95 research outputs found

    Effects of Impedance Reduction of a Robot for Wrist Rehabilitation on Human Motor Strategies in Healthy Subjects during Pointing Tasks

    Get PDF
    Studies on human motor control demonstrated the existence of simplifying strategies (namely `Donders' law') adopted to deal with kinematically redundant motor tasks. In recent research we showed that Donders' law also holds for human wrist during pointing tasks, and that it is heavily perturbed when interacting with a highly back-drivable state-of-the-art rehabilitation robot. We hypothesized that this depends on the excessive mechanical impedance of the Pronation/Supination (PS) joint of the robot and in this work we analyzed the effects of its reduction. To this end we deployed a basic force control scheme, which minimizes human-robot interaction force. This resulted in a 70% reduction of the inertia in PS joint and in decrease of 81% and 78% of the interaction torques during 1-DOF and 3-DOFs tasks. To assess the effects on human motor strategies, pointing tasks were performed by three subjects with a lightweight handheld device, interacting with the robot using its standard PD control (setting impedance to zero) and with the force-controlled robot. We quantified Donders' law as 2-dimensional surfaces in the 3-dimensional configuration space of rotations. Results revealed that the subject-specific features of Donders' surfaces reappeared after the reduction of robot impedance obtained via the force control

    Inertial-Magnetic Sensors for Assessing Spatial Cognition in Infants

    Get PDF
    This paper describes a novel approach to the assessment of spatial cognition in children. In particular we present a wireless instrumented toy embedding magneto-inertial sensors for orientation tracking, specifically developed to assess the ability to insert objects into holes. To be used in naturalistic environments (e.g. daycares), we also describe an in-field calibration procedure based on a sequence of manual rotations, not relying on accurate motions or sophisticated equipment. The final accuracy of the proposed system, after the mentioned calibration procedure, is derived by direct comparison with a gold-standard motion tracking device. In particular, both systems are subjected to a sequence of ten single-axis rotations (approximately 90 deg, back and forth), about three different axes. The root-mean-square of the angular error between the two measurements (gold-standard vs. proposed systems) was evaluated for each trial. In particular, the average rms error is under 2 deg. This study indicates that a technological approach to ecological assessment of spatial cognition in infants is indeed feasible. As a consequence, prevention through screening of large number of infants is at reach

    A Basic Geometric Framework for Quasi-Static Mechanical Manipulation

    Full text link
    In this work, we propose a geometric framework for analyzing mechanical manipulation, for example, by a robotic agent. Under the assumption of conservative forces and quasi-static manipulation, we use energy methods to derive a metric. We first review and show that the natural geometric setting is represented by the cotangent bundle and its Lagrangian submanifolds. These are standard concepts in geometric mechanics but usually presented within dynamical frameworks. We review the basic definitions from a static mechanics perspective and show how Lagrangian submanifolds are naturally derived from a first order analysis. Then, via a second order analysis, we derive the Hessian of total energy. As this is not necessarily positive-definite from a control perspective, we propose the use of the squared-Hessian for optimality measures, motivated by insights {derived from both mechanics (Gauss's Principle) and biology (Separation Principle)}. We conclude by showing how such methods can be applied, for example, to the simple case of an elastically driven pendulum. The example is simple enough to allow for analytical solution. However, an extension is further derived and numerically solved, which is more realistically connected with actual robotic manipulation problems.Comment: 28 pages, 6 figures, 1 tabl

    Design and assembly of a magneto-inertial wearable device for ecological behavioural analysis of infants

    Get PDF
    There are recent evidence which show how brain development is strictly linked to the action. Movements shape and are, in turn, shaped by cortical and sub-cortical areas. In particular spontaneous movements of newborn infants matter for developing the capability of generating voluntary skill movements. Therefore studying spontaneous infants’ movements can be useful to understand the main developmental milestones achieved by humans from birth onward. This work focuses on the design and development of a mechatronic wearable device for ecological movement analysis called WAMS (Wrist and Ankle Movement Sensor). The design and assembling of the device is presented, as well as the communication protocol and the synchronization with other marker-based optical movement analysis systems

    Learning multi-modal generative models with permutation-invariant encoders and tighter variational bounds

    Full text link
    Devising deep latent variable models for multi-modal data has been a long-standing theme in machine learning research. Multi-modal Variational Autoencoders (VAEs) have been a popular generative model class that learns latent representations which jointly explain multiple modalities. Various objective functions for such models have been suggested, often motivated as lower bounds on the multi-modal data log-likelihood or from information-theoretic considerations. In order to encode latent variables from different modality subsets, Product-of-Experts (PoE) or Mixture-of-Experts (MoE) aggregation schemes have been routinely used and shown to yield different trade-offs, for instance, regarding their generative quality or consistency across multiple modalities. In this work, we consider a variational bound that can tightly lower bound the data log-likelihood. We develop more flexible aggregation schemes that generalise PoE or MoE approaches by combining encoded features from different modalities based on permutation-invariant neural networks. Our numerical experiments illustrate trade-offs for multi-modal variational bounds and various aggregation schemes. We show that tighter variational bounds and more flexible aggregation models can become beneficial when one wants to approximate the true joint distribution over observed modalities and latent variables in identifiable models

    A Complementary Filter Design on SE(3) to IdentifyMicro-Motions during 3D Motion Tracking

    Get PDF
    In 3D motion capture, multiple methods have been developed in order to optimize thequality of the captured data. While certain technologies, such as inertial measurement units (IMU),are mostly suitable for 3D orientation estimation at relatively high frequencies, other technologies,such as marker-based motion capture, are more suitable for 3D position estimations at a lower frequencyrange. In this work, we introduce a complementary filter that complements 3D motion capture datawith high-frequency acceleration signals from an IMU. While the local optimization reduces the error ofthe motion tracking, the additional accelerations can help to detect micro-motions that are useful whendealing with high-frequency human motions or robotic applications. The combination of high-frequencyaccelerometers improves the accuracy of the data and helps to overcome limitations in motion capturewhen micro-motions are not traceable with 3D motion tracking system. In our experimental evaluation,we demonstrate the improvements of the motion capture results during translational, rotational,and combined movements

    Hyperstaticity for Ergonomic Design of a Wrist Exoskeleton

    Get PDF
    International audienceIncreasing the level of transparency in rehabilitation devices has been one of the main goals in robot-aided neurorehabilitation for the past two decades. This issue is particularly important to robotic structures that mimic the human counterpart's morphology and attach directly to the limb. Problems arise for complex joints such as the human wrist, which cannot be accurately matched with a traditional mechanical joint. In such cases, mechanical differences between human and robotic joint cause hyperstaticity (i.e. overconstraint) which, coupled with kinematic misalignments, leads to uncontrolled force/torque at the joint. This paper focuses on the prono-supination (PS) degree of freedom of the forearm. The overall force and torque in the wrist PS rotation is quantified by means of a wrist robot. A practical solution to avoid hyperstaticity and reduce the level of undesired force/torque in the wrist is presented, which is shown to reduce 75% of the force and 68% of the torque

    Is the Oxidant/Antioxidant Status Altered in CADASIL Patients?

    Get PDF
    The altered aggregation of proteins in non-native conformation is associated with endoplasmic reticulum derangements, mitochondrial dysfunction and excessive production of reactive oxygen species. Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) is a rare hereditary systemic vasculopathy, caused by NOTCH3 mutations within the receptor extracellular domain, that lead to abnormal accumulation of the mutated protein in the vascular wall. NOTCH3 misfolding could cause free radicals increase also in CADASIL. Aim of the study was to verify whether CADASIL patients have increased oxidative stress compared to unrelated healthy controls. We enrolled 15 CADASIL patients and 16 gender- and age-matched healthy controls with comparable cardiovascular risk factor. Blood and plasma reduced and total aminothiols (homocysteine, cysteine, glutathione, cysteinylglycine) were measured by HPLC and plasma 3- nitrotyrosine by ELISA. Only plasma reduced cysteine (Pr-Cys) and blood reduced glutathione (Br-GSH) concentrations differed between groups: in CADASIL patients Br-GSH levels were higher (p = 0.019) and Pr-Cys lower (p = 0.010) than in controls. No correlation was found between Br-GSH and Pr-Cys either in CADASIL patients (rho 0.25, P=0.36) or in controls (rho -0.15, P=0.44). Conversely, 3- nitrotyrosine values were similar in CADASIL and healthy subjects (p = 0.82). The high levels of antioxidant molecules and low levels of oxidant mediators found in our CADASIL population might either be expression of an effective protective action against free radical formation at an early stage of clinical symptoms or they could suggest that oxidative stress is not directly involved in the pathogenesis of CADASIL
    • …
    corecore